49 CFR § 192.463 Transportation of Natural and Other Gas by Pipeline: Minimum Federal Safety Standards

§ 192.463 External corrosion control: Cathodic protection.

Current through Sep 25, 2026 · Read all of Part 192

⚠ 31 pending changes to Part 192

(a) Each cathodic protection system required by this subpart must provide a level of cathodic protection that complies with one or more of the applicable criteria contained in appendix D of this part. If none of these criteria is applicable, the cathodic protection system must provide a level of cathodic protection at least equal to that provided by compliance with one or more of these criteria.

(b) If amphoteric metals are included in a buried or submerged pipeline containing a metal of different anodic potential—

(1) The amphoteric metals must be electrically isolated from the remainder of the pipeline and cathodically protected; or

(2) The entire buried or submerged pipeline must be cathodically protected at a cathodic potential that meets the requirements of appendix D of this part for amphoteric metals.

(c) The amount of cathodic protection must be controlled so as not to damage the protective coating or the pipe.

← § 192.461 External corrosion control: Protective coating.§ 192.465 External corrosion control: Monitoring and remediation. →