46 CFR § 154.540 Safety Standards for Self-Propelled Vessels Carrying Bulk Liquefied Gases

§ 154.540 Quick-closing shut-off valves: Emergency shut-down system.

Current through Sep 25, 2026 · Read all of Part 154

The quick-closing shut-off valves under §§ 154.530, 154.532, and 154.538 must have an emergency shut-down system that:

(a) Closes all the valves;

(b) Is actuated by a single control in at least two locations remote from the quick-closing valves;

(c) Is actuated by a single control in each cargo control station under § 154.320; and

(d) Has fusible elements at each tank dome and cargo loading and discharge manifold that melt between 98 °C (208 °F) and 104 °C (220 °F) and actuate the emergency shut-down system.

← § 154.538 Cargo transfer connection.§ 154.544 Quick-closing shut-off valves. →