40 CFR § 424.72 Ferroalloy Manufacturing Point Source Category

§ 424.72 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.

Current through Aug 22, 2025 · Read all of Part 424

Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):

Effluent characteristicEffluent limitations
Maximum for any 1 dayAverage of daily values for 30 consecutive days shall not exceed—
Metric units (kg/kkg of product)
TSS5.2762.638
Manganese2.1111.055
Chromium0.1060.053
Ammonia-N10.5535.276
pH( 1)( 1)
English units (lb/1,000 lb of product)
TSS5.2762.638
Manganese2.1111.055
Chromium0.1060.053
Ammonia-N10.5535.276
pH( 1)( 1)

1 Within the range 6.0 to 9.0.

[40 FR 8037, Feb. 27, 1975, as amended at 60 FR 33957, June 29, 1995]

← § 424.71 Specialized definitions.§ 424.73 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable. →