30 CFR § 75.205 Mandatory Safety Standards—Underground Coal Mines

§ 75.205 Installation of roof support using mining machines with integral roof bolters.

Current through Jul 27, 2026 · Read all of Part 75

⚠ 3 pending changes to Part 75

When roof bolts are installed by a continuous mining machine with integral roof bolting equipment:

(a) The distance between roof bolts shall not exceed 10 feet crosswise.

(b) Roof bolts to be installed 9 feet or more apart shall be installed with a wooden crossbar at least 3 inches thick and 8 inches wide, or material which provides equivalent support.

(c) Roof bolts to be installed more than 8 feet but less than 9 feet apart shall be installed with a wooden plank at least 2 inches thick and 8 inches wide, or material which provides equivalent support.

← § 75.204 Roof bolting.§ 75.206 Conventional roof support. →